# LC resonance: estimate before measuring

Nominal calculation, tolerances, and measurement preparation: a short method for reaching the bench with values that can be checked.

https://elmehdi-essamit.me/en/notes/resonance-et-tolerances/

## Start with the model and the units

In an ideal LC model, natural frequency depends on inductance L and capacitance C. The formula takes henrys and farads and returns hertz. It gives a starting point for choosing a measurement range.

`f₀ = 1 / (2π√LC)`

Teaching example, independent of my TIPE values: L = 4.7 mH and C = 4.7 nF give f₀ ≈ 33.86 kHz. Before comparing with the bench, write 4.7 × 10⁻³ H and 4.7 × 10⁻⁹ F to check the prefixes.

[OpenStax · Oscillations in an LC circuit](https://openstax.org/books/university-physics-volume-2/pages/14-5-oscillations-in-an-lc-circuit)

## Calculate both extremes

Frequency decreases when L or C increases. For relative tolerances tL and tC, the largest component values therefore give the minimum frequency. The smallest give the maximum.

`fmin = f₀ / √((1 + tL)(1 + tC))
fmax = f₀ / √((1 − tL)(1 − tC))`

With ±5% on each component, this example gives approximately 32.25 to 35.65 kHz. These bounds describe the extremes of the ideal model; they are neither a confidence interval nor an efficiency prediction. Tolerances here are fractions: 5% = 0.05.

[Try the calculator and export the values](https://elmehdi-essamit.me/en/lab/)

## Prepare a useful comparison

To compare a calculation with a measurement, retain nominal values, measured values if available, the load, and instrument settings. For two coils, also record spacing and orientation.

- Label voltages with an explicit convention: RMS, peak, or peak-to-peak.
- Keep raw measurements beside the plot and record each setup change.
- Distinguish the calculated frequency, observed peak, and protocol limitations.

Resistance, load, coupling, and parasitic elements are absent from this LC calculation. An experimental mismatch calls for checking assumptions and the procedure, without silently adjusting data.

[Download a blank measurement log · CSV](https://elmehdi-essamit.me/assets/measurement-log.csv)